  • YST665Y Pneumatic Y type steam trap valve

    ( For Power plant drain water )

    • Port size:DN20-100(3/4”-4”)
    • Pressure: PN1.6-32Mpa(ANSI150-2500LB)
    • Medium:Water,steam
    • Temperature: 20C°-570C°
    • Material:WCB WC6 WC9 CF8 CF3 CF8M CF3M
    • Characteristic:Linear
    • Connection:BW,SW
    • Other:Pneumatic or electric actuator is optional
  • T966Y Electric multistage step-down control valve

    ( Angle type for high pressure difference )

    • Port size:DN25-50(1”-2”)
    • Pressure: PN25、32Mpa(ANSI 1500、2500LB)
    • Medium:Water,oil,steam,gas
    • Temperature:-29~420℃
    • Material:WCB WC6 WC9 CF8 CF8M or others
    • Characteristic:Linear, Equal percentage
    • Connection:Flanged,butt weld is optional
    • Other:Pneumatic or electric actuator is optional
  • T968Y Electric high pressure difference control valve

    ( multi-level, multi-hole cage balanced trim structure )

    • Port size:DN65-250(2.5”-10”)
    • Pressure: PN16 ~ 100,150LB ~ 600LB
    • Medium:Water,oil,steam,gas
    • Temperature:-29~425℃
    • Material:WCB WC6 WC9 CF8 CF3 CF8M CF3M
    • Characteristic:Linear, Equal percentage
    • Connection:Flanged,butt weld is optional
    • Other:Pneumatic actuator is optional
  • Electric Y-type trap drain control valve

    ( For discharging the steam-water mixtures )

    • Port size:DN20~100, NPS 3/4〞~ 4〞
    • Pressure: PN1.6-32Mpa(ANSI150-2500LB)
    • Medium:Water,steam
    • Temperature:20C°-570C°
    • Material:WCB A105 WC6 WC9 F11 F22
    • Characteristic:Linear
    • Connection:SW,BW
    • Other:Pneumatic or electric actuator is optional
  • Pneumatic Y-type trap drain control valve

    ( For discharging the steam-water mixtures )

    • Port size:DN20~100, NPS 3/4〞~ 4〞
    • Pressure: PN1.6-32Mpa(ANSI150-2500LB)
    • Medium:Water,steam
    • Temperature:20C°-570C°
    • Material:WCB A105 WC6 WC9 F11 F22
    • Characteristic:Linear
    • Connection:SW,BW
    • Other:Pneumatic or electric actuator is optional
  • HP heater emergency drain control valve

    ( For HP heater emergency drain system )

    • Port size:DN100~200, NPS 4〞~ 8〞
    • Pressure: PN40 ~ 100,150LB ~ 600LB
    • Medium:Water,steam
    • Temperature:≤260℃
    • Material:WCB
    • Characteristic:Linear, Equal percentage
    • Connection:Flange,welding
    • Other:Pneumatic or electric actuator is optional
  • Electric HP heater drain control valve

    ( For HP heater draining system )

    • Port size:DN65~250, NPS 2.5〞~ 10〞
    • Pressure: PN16 ~ 100,150LB ~ 600LB
    • Medium:Water,steam
    • Temperature:≤420℃
    • Material:WCB
    • Characteristic:Linear, Equal percentage
    • Connection:Flange,welding
    • Other:Pneumatic or electric actuator is optional
  • Pneumatic HP heater drain control valve

    ( For HP heater draining system )

    • Port size:DN65~250, NPS 2.5〞~ 10〞
    • Pressure: PN16 ~ 100,150LB ~ 600LB
    • Medium:Water,steam
    • Temperature:≤420℃
    • Material:WCB
    • Characteristic:Linear, Equal percentage
    • Connection:Flange,welding
    • Other:Pneumatic or electric actuator is optional
  • Pneumatic high pressure bypass control valve

    ( For reheating unit bypass systems )

    • Port size:inlet DN125 (5”) outlet DN300(12”)
    • Pressure: PN25~32Mpa(1500~2500LB)
    • Medium:Water,steam
    • Temperature:-29~550℃
    • Material:WC6 WC9 F11 F22
    • Characteristic:Linear, Equal percentage, quick open
    • Connection:SW,BW,Flange is optioanl
    • Other:Pneumatic or electric actuator is optional
  • Electric high pressure bypass control valve

    ( For reheating unit bypass systems )

    • Port size:inlet DN125 (5”) outlet DN300(12”)
    • Pressure: PN25~32Mpa(ANSI 1500~2500LB)
    • Medium:Water,steam
    • Temperature:-29~550℃
    • Material:WC6 WC9 F11 F22
    • Characteristic:Linear, Equal percentage, quick open
    • Connection:BW,SW,flanged
    • Other:Pneumatic or electric actuator is optional
  • Pneumatic boiler feedwater control valve

    ( For boiler feedwater system )

    • Port size:DN50~300, NPS 2〞~ 12〞
    • Pressure: PN25~32Mpa(1500~2500LB)
    • Medium:Water,steam
    • Temperature:-29~420℃
    • Material:WCB
    • Characteristic:Linear, Equal percentage, quick open
    • Connection:Flange,welding
    • Other:Pneumatic or electric actuator is optional
  • Electric boiler feed water control valve

    ( For boiler feed water system )

    • Port size:DN50~300, NPS 2〞~ 12〞
    • Pressure: PN25~32Mpa(ANSI 1500~2500LB)
    • Medium:Water,steam
    • Temperature:-29~420℃
    • Material:WCB
    • Characteristic:Linear, Equal percentage, quick open
    • Connection:SW,BW,Flange is optioanl
    • Other:Pneumatic or electric actuator is optional
  • Pneumatic main steam trap control valve

    ( For main steam pipeline )

    • Port size:DN25~50, NPS 1〞~ 2〞
    • Pressure: PN25~32Mpa(1500~2500LB)
    • Medium:Water,steam
    • Temperature:-29~570℃
    • Material:WC6 WC9 F11 F22
    • Characteristic:Linear, Equal percentage, quick open
    • Connection:Flange,welding
    • Other:Pneumatic or electric actuator is optional
  • Electric main steam trap control valve

    ( For main steam pipeline )

    • Port size:DN25~50, NPS 1〞~ 2〞
    • Pressure: PN25~32Mpa(1500~2500LB)
    • Medium:Water,steam
    • Temperature:-29~570℃
    • Material:WC6 WC9 F11 F22
    • Characteristic:Linear, Equal percentage, quick open
    • Connection:Flange,welding
    • Other:High pressure drop
  • Electric desuperheater control valve

    ( Different body structure is optional )

    • Port size:DN25~50, NPS 1〞~ 2〞
    • Pressure: PN25~32Mpa(1500~2500LB)
    • Medium:Water,oil,steam,gas
    • Temperature:-29~420℃
    • Material:WCB A105
    • Characteristic:Linear, Equal percentage, quick open
    • Connection:SW,BW,Flange is optioanl
    • Other:Electric and pneumatic actuator is optional
  • Pneumatic desuperheater control valve

    ( Different body structure is optional )

    • Port size:DN25~50, NPS 1〞~ 2〞
    • Pressure: PN25~32Mpa (1500~2500LB)
    • Medium:Water,oil,steam,gas
    • Temperature:-29~420℃
    • Material:WCB A105
    • Characteristic:Linear, percentage, quick open
    • Connection:SW,BW,Flange is optioanl
    • Other:Pneumatic or electric actuator is optional
  • Boiler continuous blowdown control valve

    ( Boiler continuous blowdown valve )

    • Port size:DN25~50, NPS 1〞~ 2〞
    • Pressure: PN25~32Mpa(1500~2500LB)
    • Medium:Water,oil,steam,gas
    • Temperature:-29~420℃
    • Material:WCB A105
    • Characteristic:Linear, Equal percentage
    • Connection:SW,BW,Flange is optioanl
    • Other:Electric or Pneumatic is optional
  • boiler intermittent blowdown control valve

    ( boiler intermittent blowdown valve )

    • Port size:DN25~50, NPS 1〞~ 2〞
    • Pressure: PN25~32Mpa(1500~2500LB)
    • Medium:Water,air,gas
    • Temperature:-29~420℃
    • Material:WCB A105
    • Characteristic:Linear, Equal percentage
    • Connection:SW,BW,Flange is optioanl
    • Other:Diaphragm and piston actuator is for optional
  • Pneumatic boiler blowdown control valve

    ( boiler intermittent blowdown valve )

    • Port size:DN25~50, NPS 1〞~ 2〞
    • Pressure: PN25~32Mpa(1500~2500LB)
    • Medium:Water,steam,gas
    • Temperature:-29~420℃
    • Material:WCB A105
    • Characteristic:Linear, Equal percentage
    • Connection:SW,BW,Flange is optioanl
    • Other:diaphragm or piston actuator is optional
  • Electric boiler blowdown control valve

    ( boiler intermittent blowdown valve )

    • Port size:DN25~50, NPS 1〞~ 2〞
    • Pressure: PN25~32Mpa(1500~2500LB)
    • Medium:Water,steam,gas
    • Temperature:-29~420℃
    • Material:WCB A105
    • Characteristic:Linear, Equal percentage
    • Connection:BW,SW,flanged
    • Other:Electric and pneumatic actuator is optional
  • Minimum flow recirculation control valve

    ( For power plant’s boiler feedwater pump system )

    • Port size:DN20~300, NPS 3/4〞~ 12〞
    • Pressure: PN25~32Mpa(1500~2500LB)
    • Medium:water,Steam
    • Temperature:-40~450℃
    • Material:WCB,A105,WC6,WC9,F11,F22
    • Characteristic:Linear, Equal percentage, quick open
    • Connection:BW,SW
    • Other: